Server IP : 66.29.132.122 / Your IP : 3.148.113.219 Web Server : LiteSpeed System : Linux business142.web-hosting.com 4.18.0-553.lve.el8.x86_64 #1 SMP Mon May 27 15:27:34 UTC 2024 x86_64 User : admazpex ( 531) PHP Version : 7.2.34 Disable Function : NONE MySQL : OFF | cURL : ON | WGET : ON | Perl : ON | Python : ON | Sudo : OFF | Pkexec : OFF Directory : /proc/thread-self/root/proc/self/root/usr/share/snmp/mibs/ |
Upload File : |
LM-SENSORS-MIB DEFINITIONS ::= BEGIN -- -- Derived from the original VEST-INTERNETT-MIB. Open issues: -- -- (a) where to register this MIB? -- (b) use not-accessible for diskIOIndex? -- IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Gauge32 FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC ucdExperimental FROM UCD-SNMP-MIB; lmSensorsMIB MODULE-IDENTITY LAST-UPDATED "200011050000Z" ORGANIZATION "AdamsNames Ltd" CONTACT-INFO "Primary Contact: M J Oldfield email: m@mail.tc" DESCRIPTION "This MIB module defines objects for lm_sensor derived data." REVISION "200011050000Z" DESCRIPTION "Derived from DISKIO-MIB ex UCD." ::= { lmSensors 1 } lmSensors OBJECT IDENTIFIER ::= { ucdExperimental 16 } -- lmTempSensorsTable OBJECT-TYPE SYNTAX SEQUENCE OF LMTempSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of temperature sensors and their values." ::= { lmSensors 2 } lmTempSensorsEntry OBJECT-TYPE SYNTAX LMTempSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing a device and its statistics." INDEX { lmTempSensorsIndex } ::= { lmTempSensorsTable 1 } LMTempSensorsEntry ::= SEQUENCE { lmTempSensorsIndex Integer32, lmTempSensorsDevice DisplayString, lmTempSensorsValue Gauge32 } lmTempSensorsIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Reference index for each observed device." ::= { lmTempSensorsEntry 1 } lmTempSensorsDevice OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the temperature sensor we are reading." ::= { lmTempSensorsEntry 2 } lmTempSensorsValue OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature of this sensor in mC." ::= { lmTempSensorsEntry 3 } -- lmFanSensorsTable OBJECT-TYPE SYNTAX SEQUENCE OF LMFanSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of fan sensors and their values." ::= { lmSensors 3 } lmFanSensorsEntry OBJECT-TYPE SYNTAX LMFanSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing a device and its statistics." INDEX { lmFanSensorsIndex } ::= { lmFanSensorsTable 1 } LMFanSensorsEntry ::= SEQUENCE { lmFanSensorsIndex Integer32, lmFanSensorsDevice DisplayString, lmFanSensorsValue Gauge32 } lmFanSensorsIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Reference index for each observed device." ::= { lmFanSensorsEntry 1 } lmFanSensorsDevice OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the fan sensor we are reading." ::= { lmFanSensorsEntry 2 } lmFanSensorsValue OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The rotation speed of the fan in RPM." ::= { lmFanSensorsEntry 3 } -- lmVoltSensorsTable OBJECT-TYPE SYNTAX SEQUENCE OF LMVoltSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of voltage sensors and their values." ::= { lmSensors 4 } lmVoltSensorsEntry OBJECT-TYPE SYNTAX LMVoltSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing a device and its statistics." INDEX { lmVoltSensorsIndex } ::= { lmVoltSensorsTable 1 } LMVoltSensorsEntry ::= SEQUENCE { lmVoltSensorsIndex Integer32, lmVoltSensorsDevice DisplayString, lmVoltSensorsValue Gauge32 } lmVoltSensorsIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Reference index for each observed device." ::= { lmVoltSensorsEntry 1 } lmVoltSensorsDevice OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the device we are reading." ::= { lmVoltSensorsEntry 2 } lmVoltSensorsValue OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage in mV." ::= { lmVoltSensorsEntry 3 } -- lmMiscSensorsTable OBJECT-TYPE SYNTAX SEQUENCE OF LMMiscSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of miscellaneous sensor devices and their values." ::= { lmSensors 5 } lmMiscSensorsEntry OBJECT-TYPE SYNTAX LMMiscSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing a device and its statistics." INDEX { lmMiscSensorsIndex } ::= { lmMiscSensorsTable 1 } LMMiscSensorsEntry ::= SEQUENCE { lmMiscSensorsIndex Integer32, lmMiscSensorsDevice DisplayString, lmMiscSensorsValue Gauge32 } lmMiscSensorsIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Reference index for each observed device." ::= { lmMiscSensorsEntry 1 } lmMiscSensorsDevice OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the device we are reading." ::= { lmMiscSensorsEntry 2 } lmMiscSensorsValue OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this sensor." ::= { lmMiscSensorsEntry 3 } END