Server IP : 66.29.132.122 / Your IP : 18.117.141.149 Web Server : LiteSpeed System : Linux business142.web-hosting.com 4.18.0-553.lve.el8.x86_64 #1 SMP Mon May 27 15:27:34 UTC 2024 x86_64 User : admazpex ( 531) PHP Version : 7.2.34 Disable Function : NONE MySQL : OFF | cURL : ON | WGET : ON | Perl : ON | Python : ON | Sudo : OFF | Pkexec : OFF Directory : /proc/self/root/proc/self/root/proc/self/root/lib/dracut/modules.d/99base/ |
Upload File : |
#!/bin/bash # called by dracut check() { return 0 } # called by dracut depends() { echo udev-rules return 0 } # called by dracut install() { local _d inst_multiple mount mknod mkdir sleep chroot chown \ sed ls flock cp mv dmesg rm ln rmmod mkfifo umount readlink setsid inst $(command -v modprobe) /sbin/modprobe inst_multiple -o findmnt less kmod if [ ! -e "${initdir}/bin/sh" ]; then inst_multiple bash (ln -s bash "${initdir}/bin/sh" || :) fi #add common users in /etc/passwd, it will be used by nfs/ssh currently grep '^root:' "$initdir/etc/passwd" 2>/dev/null || echo 'root:x:0:0::/root:/bin/sh' >> "$initdir/etc/passwd" grep '^nobody:' /etc/passwd >> "$initdir/etc/passwd" # install our scripts and hooks inst_script "$moddir/init.sh" "/init" inst_script "$moddir/initqueue.sh" "/sbin/initqueue" inst_script "$moddir/loginit.sh" "/sbin/loginit" inst_script "$moddir/rdsosreport.sh" "/sbin/rdsosreport" [ -e "${initdir}/lib" ] || mkdir -m 0755 -p ${initdir}/lib mkdir -m 0755 -p ${initdir}/lib/dracut mkdir -m 0755 -p ${initdir}/lib/dracut/hooks mkdir -p ${initdir}/tmp inst_simple "$moddir/dracut-lib.sh" "/lib/dracut-lib.sh" mkdir -p "${initdir}/var" if ! dracut_module_included "systemd"; then inst_multiple switch_root || dfatal "Failed to install switch_root" inst_hook cmdline 10 "$moddir/parse-root-opts.sh" inst_multiple -o $systemdutildir/systemd-timestamp fi if [[ $realinitpath ]]; then for i in $realinitpath; do echo "rd.distroinit=$i" done > "${initdir}/etc/cmdline.d/distroinit.conf" fi ln -fs /proc/self/mounts "$initdir/etc/mtab" if [[ $ro_mnt = yes ]]; then echo ro >> "${initdir}/etc/cmdline.d/base.conf" fi local VERSION="" local PRETTY_NAME="" if [ -e /etc/os-release ]; then . /etc/os-release [[ -n ${VERSION} ]] && VERSION+=" " [[ -n ${PRETTY_NAME} ]] && PRETTY_NAME+=" " fi NAME=dracut ID=dracut VERSION+="dracut-$DRACUT_VERSION" PRETTY_NAME+="dracut-$DRACUT_VERSION (Initramfs)" VERSION_ID=$DRACUT_VERSION ANSI_COLOR="0;31" [ -e "${initdir}/usr/lib" ] || mkdir -m 0755 -p ${initdir}/usr/lib { echo NAME=\"$NAME\" echo VERSION=\"$VERSION\" echo ID=$ID echo VERSION_ID=$VERSION_ID echo PRETTY_NAME=\"$PRETTY_NAME\" echo ANSI_COLOR=\"$ANSI_COLOR\" } > $initdir/usr/lib/initrd-release echo dracut-$DRACUT_VERSION > $initdir/lib/dracut/dracut-$DRACUT_VERSION ln -sf ../usr/lib/initrd-release $initdir/etc/initrd-release ln -sf initrd-release $initdir/usr/lib/os-release ln -sf initrd-release $initdir/etc/os-release ## save host_devs which we need bring up if [[ $hostonly_cmdline == "yes" ]]; then if [[ -n "${host_devs[@]}" ]]; then dracut_need_initqueue fi if [[ -f "$initdir/lib/dracut/need-initqueue" ]] || ! dracut_module_included "systemd"; then ( if dracut_module_included "systemd"; then DRACUT_SYSTEMD=1 fi PREFIX="$initdir" . "$moddir/dracut-lib.sh" for _dev in "${host_devs[@]}"; do for _dev2 in "${root_devs[@]}"; do [[ "$_dev" == "$_dev2" ]] && continue 2 done # We only actually wait for real devs - swap is only needed # for resume and udev rules generated when parsing resume= # argument take care of the waiting for us for _dev2 in "${swap_devs[@]}"; do [[ "$_dev" == "$_dev2" ]] && continue 2 done _pdev=$(get_persistent_dev $_dev) case "$_pdev" in /dev/?*) wait_for_dev $_pdev;; *) ;; esac done ) fi fi }